By Code Consultants Inc.

ISBN-10: 146143839X

ISBN-13: 9781461438397

ISBN-10: 1461438403

ISBN-13: 9781461438403

Antifreeze ideas in domestic fireplace Sprinkler structures examines the use of antifreeze ideas in residential sprinklers, and analyzes their effectiveness in controlling a fireplace situation and supporting in containment. The publication additionally investigates the potential of a large-scale ignition taking place from recommendations of various combinations, and proposes the optimum ones for decreasing flammability. 

Antifreeze options in domestic hearth Sprinkler structures is designed for practitioners as a reference advisor for dealing with antifreeze strategies in residential sprinkler platforms. Researchers operating in a similar box also will locate the booklet valuable.

Show description

Read or Download Antifreeze Solutions in Home Fire Sprinkler Systems PDF

Best quality control books

Download PDF by Robert L. Baber: Error Free Software: Know-How and Know-Why of Program

Strain to supply quality software program inside of funds leaves little scope to discover the speculation and strength of formal improvement equipment. This creation to the production and improvement of software program goals to illustrate a variety of benefits to be won by utilizing yes options. All thoughts defined are in keeping with mathematical foundations, and a uncomplicated wisdom of algebra and programming is thought.

Lev M. Klyatis's Accelerated Reliability and Durability Testing Technology PDF

Learn the way artwork and ADT can lessen price, time, product recollects, and purchaser complaintsThis ebook offers engineers with the concepts and instruments they should use sped up reliability trying out (ART) and speeded up sturdiness checking out (ADT) as key elements to correctly are expecting a product's caliber, reliability, toughness, and maintainability in the course of a given time, akin to carrier existence or guaranty interval.

New PDF release: Standpipe Systems for Fire Protection

This crucial new handbook is going past the broadcast NFPA criteria on deploy of standpipe structures to incorporate the foundations within the foreign development Code, municipal fireplace codes, the nationwide hearth Code of Canada, and knowledge on inspection, trying out, and upkeep of standpipe structures. additionally lined are the interactions among standpipe and sprinkler structures, considering those vital hearth safety platforms are so usually put in jointly.

Extra resources for Antifreeze Solutions in Home Fire Sprinkler Systems

Example text

Results of the tests are summarized in Fig. 18, below, which shows the increase in heat release rate due to the change in ceiling height for each antifreeze solution using the same sprinkler and ignition source. 1 Sprinkler 8' -60% Propylene Glycol 8' -50% Propylene Glycol 8' - 40% Propylene Glycol 20' - 60% Propylene Glycol 20'- 50% Propylene Glycol 20' - 40% Propylene Glycol 6,000 5,000 4,000 3,000 2,000 1,000 0 0 5 10 15 20 25 30 35 40 -1,000 Sprinkler Flow Rate (gpm) Fig. 18 Comparison of Results Based on Sprinkler Height The results presented above show that for 40% and 60% propylene glycol solutions, the height of the sprinkler had a less significant effect on the increase in heat release rate.

Htm 11. V. Babrauskas, Ignition Handbook. Issaquah, WA: Fire Science Publishers, 2003. 12. National Fire Protection Association, “Fire Hazard Properties of Flammable Liquids, Gases, and Volatile Solids,” Quincy, MA, NFPA 325M, 1991. 13. S. , Lees’ Loss Prevention in the Process Industries: Hazard Identification, Assessment and Control, 3rd ed. , 2005. 14. G. S. Dept. of the Interior, Bureau of Mines, Bulletin 627, 1965. 15. M. S. Dept. of the Interior, Bureau of Mines, Bulletin 680, 1985. 16. Noble Company.

The following observations and analysis provides additional insight into the fire test data discussed above. A Observations The Scope A ignition tests conducted with the heptane spray burner were unique in that the ignition source had a steady heat release rate that was not significantly impacted by the antifreeze spray and the ignition source could not readily be extinguished by the antifreeze spray. e. the fuel contributed by the spray burner was a function of the heptane flow rate and was not impacted by the antifreeze spray.

Download PDF sample

Antifreeze Solutions in Home Fire Sprinkler Systems by Code Consultants Inc.


by Jason
4.4

Rated 4.00 of 5 – based on 39 votes